欢迎进入上海韦米机电设备有限公司官网!

产品中心

韦米机电主营欧美、日韩液压元件、气动元件、工控电气等进口备件

  • 产品名称: 力士乐Rexroth比例减压阀ZDRE10VP4X-1X/250YMG24-8Z4M
  • 所属类别: 力士乐先导式比例减压阀

产品简述

力士乐Rexroth比例减压阀ZDRE10VP4X-1X/250YMG24-8Z4M是上海韦米机电设备有限公司的【重点优势产品】之一

电话Tel:021-61116912   

手机Cel:13524122975 (微信同号)

在线Q Q:2532163287 

E-mail:fred@wei-mi.com

欢迎来电咨询或加QQ、微信在线联系!



详细说明

力士乐Rexroth比例减压阀ZDRE10VP4X-1X/250YMG24-8Z4M


比例减压阀属高压阀系列,适用于冶金、石油、液压、水压试验机组上。主要用途:是采用节流耗能达到降压的功能,能使高压、超高压设备和高压管道内的高压水通过此阀将高压水降至低压所需压力后排出,使高压系统压力均匀降低。

力士乐Rexroth比例减压阀DRE4K-3X/30G24-10K4M

R900954474 3DREP 6 A-2X/16EG24K4/M

R900954417 3DREP 6 A-2X/25EG24K4/M

R900954418 3DREP 6 A-2X/45EG24K4/M

R900954419 3DREP 6 C-2X/16EG24K4/M

R900954420 3DREP 6 C-2X/25EG24K4/M

R900954421 3DREP 6 C-2X/45EG24K4/M

R900954422 3DREPE 6 A-2X/16EG24K31/A1M

R900954423 3DREPE 6 A-2X/25EG24K31/A1M

R900954424 3DREPE 6 A-2X/45EG24K31/A1M

R900954425 3DREPE 6 C-2X/16EG24K31/A1M

R900954427 3DREPE 6 C-2X/25EG24K31/A1M

R900954428 3DREPE 6 C-2X/45EG24K31/A1M

Rexroth比例减压阀3DREP6A-2X/16EG24K4/M

比例减压阀由油缸、阀体两部分组成。而节流孔板和高压调节阀设计为一体,阀门开关排泄流量和降压由液压缸行程控制。能任意调整排泄压力及流量,安全,方便。

比例减压阀:压降从50兆帕至于1.6兆帕,可以调节排泄压力。



比例减压阀工作原理:

导阀的开启都是利用顶部的调节螺栓顺时针方向拧动,使弹簧缩产生的弹力,使导阀膜片向下凹陷,作用在导阀连杆上的力,使之向下位移打开导阀。当导阀开启后,上游进汽管段A腔的蒸汽通过α通道(供汽调节通道),经过导阀进入导阀环形汽腔,由β通道直接送到下面的活塞汽缸上腔。在A腔蒸汽不断的供给下,压力持续升高,推动活塞下行打开主阀,这时蒸汽源源不断从A腔流至B腔。当下游出口管段B腔负荷满足的情况下,余多的蒸汽又使B腔内的压力不断升高。不断升高的压力通过γ通道(压力感应通道)反馈到导阀膜片下腔,使导阀膜片向上突起,克服了上部调节弹簧的压力,导阀被关小或关闭。从而,关小或关闭来自上游α通道的蒸汽源。当活塞汽缸上腔压力下降时,在下面复位弹簧的作用下,主阀被关小或关闭,这时B腔内的压力开始下降,这样周而复始达到调压的目的。



型号 (Z)DRE and ZDREE 10 

比例减压阀,先导式


规格6和10 

安装面按DIN 24340 A型和ISO 4401 

用于降低系统压力的阀 

比例电磁铁操作 

底板安装,DRE 6型 

叠加式,ZDRE 6 和10型 

线性压力/指令值特性曲线 

集成电控器(OBE),用于ZDREE 10 



型号 DRE(M) 和 DRE(M)E 

比例减压阀,先导式


规格10至32 

安装面按DIN 24340 D型 

用于降低系统压力的阀 

比例电磁铁操作 

底板安装 

线性压力/指令值特性曲线 

用于DREM和DREME型的最大减压功能 

可选单向阀,在A和B油口之间 

集成电控器(OBE),用于DREE和DREME


Rexroth比例减压阀3DREME10P-7X/200YG24K31F1V

型号 DRE 

比例减压阀,先导式


规格6和10 

规格6:安装面按ISO 4401 

规格10:安装面按ISO 5781-AG-06-2-A 

用于降低系统压力的阀 

比例电磁铁操作 

通过电磁铁电枢位置进行调节 

DREBE型的集成电控器(OBE)


型号 3DRE(M) 和 3DRE(M)E 

比例减压阀,先导式


规格10和16 

安装面按DIN 24340 A型和ISO 4401 

用于降低系统压力的阀 

比例电磁铁操作 

底板安装 

用于3DREE and 3DREME的集成电控器(OBE) 



型号 DRS and ZDRS 

比例减压阀,先导式,有直流马达操作


规格6 

安装面按ISO 4401 

用于降低系统压的阀,有溢流功能 

直流马达操作 

底板安装 

作为叠加阀 

集成压力监测,可选


R900936785 ZDREE10VP2-1X/50XLMG24NK31M 936785

R900935959 DREME10-5X/200YMG24K31M 935959

R900935786 DRE20-5X/200YG24NK4M 935786

R900935785 DRE20-5X/100YG24NK4M 935785

R900935754 ZDREE10VP2-1X/315XLMG24NK31M 935754

R900934478 ZDREE10VP2-1X/100LMG24NK31V 934478

R900932943 DRE6-1X/100MG24K4M 932943

R900932154 3DREP6C-2X/25EG24K4/V 932154

R900931312 DRE10-5X/100YG24NK4M 931312

R900931050 3DREPE6B-2X/25EG24N9K31/A1V 931050

R900930942 ZDRE6VP2-1X/100MG24K4M 930942

R900929865 3DREPE6B-2X/45EG24N9K31/A1V=LB 929865

R900929763 DRE10-5X/315YG24K4M 929763

R900929529 3DREP6C-2X/25EG24N9K4/V 929529

R900928873 DRE6-1X/210MG24K4M 928873

R900928552 DREM10-5X/200YG24NK4M 928552

R900928329 DRE10-5X/200YMG24NK4M 928329

R900927618 DREE20-5X/315YMG24NK31M 927618

R900926984 3DREPE6C-2X/25EG24N9K31/F1V 926984

R900926930 DRE10-5X/200YMG24K4M 926930

R900926631 3DREP6A-1X/25A24N9K4M 926631

R900926157 ZDRE6VP4-1X/100MG24NK4M 926157

R900925707 3DREPEB6C-2X/25EG24N9K31/A1V 925707

R900925527 3DREPE6C-2X/25EG24K31/A1V 925527

R900925526 3DREPE6A-2X/25EG24N9K31/A1V 925526

R900925484 3DREPE6C-2X/25EG24N9K31/A1V 925484

R900925066 DREME10-5X/200YG24K31M 925066

R900925013 3DREPE6B-2X/45EG24N9K31/A1V 925013

R900924796 DREM10-5X/315YG24K4V 924796

R900924326 DREME20-5X/315YG24K31M 924326

R900923432 DREE10-5X/200YMG24NK31M 923432

R900923187 DREM20-5X/315YG24K4M 923187

R900923017 ZDREE10VP2-1X/200XLMG24NK31M 923017

R900922925 DRE20-5X/315YG24K4M 922925

R900921798 ZDREE10VP2-1X/100XLMG24NK31M 921798

R900920814 DREME10-5X/100YG24K31M 920814

R900920580 DREE10-5X/100YG24NK31M 920580

R900918272 DREME20-5X/200YMG24K31M 918272

R900917728 DRE10-5X/200YG24K4M 917728

R900917218 3DREP6B-1X/25A24N9K4M 917218

R900916266 DRE20-5X/200YG24K4M 916266

R900916199 DRE20-5X/315YMG24K4M 916199

R900916198 DRE20-5X/100YG24K4M 916198

R900916197 DRE10-5X/200YG24NK4M 916197

R900916196 DRE10-5X/315YMG24K4M 916196

R900916195 DRE6-1X/50MG24NK4M 916195

R900915981 DREM20-5X/315YMG24K4M 915981

R900915979 DREM20-5X/200YG24K4M 915979

R900915976 DREM20-5X/100YG24NK4M 915976

R900915975 DREM10-5X/50YG24K4M 915975

R900915974 DREM10-5X/315YG24K4M 915974

R900915973 DREM10-5X/200YMG24K4M 915973

R900915972 DREM10-5X/200YG24K4M 915972

R900915969 DREM10-5X/100YG24K4M 915969

R900915966 ZDRE6VP4-1X/210MG24K4M 915966

R900915963 ZDRE6VP2-1X/210MG24K4M 915963

R900915961 ZDRE6VP1-1X/50MG24NK4M 915961

R900915955 ZDRE10VP3-1X/100XLMG24NK4M 915955

R900915954 ZDRE10VP2-1X/315XLMG24NK4M 915954

R900915951 ZDRE10VP1-1X/200YMG24NK4M 915951

R900912137 ZDRE10VP4-1X/200XLMG24NK4M 912137

R900907850 DREM10-5X/315YMG24K4M 907850

R900901953 DRE6-1X/210MG24NK4M 901953

R900900653 DRE10-5X/100YG24K4M 900653

R900779370 DRE20-5X/200YG24NK4V 779370

R900769060 3DREM16P-6X/250XYG24K4V-2 769060

R900768957 LFA40DREV-7X/006/12 768957

R900766041 ZDRE10VP2-1X/50XLMG24K4M 766041

R900756822 DRE20-5X/315YMG24K4V 756822

R900748593 ZDRE6VP1-1X/100MG24K4V-5 748593

R900748507 DRE6-1X/100MG24NK4V-5 748507

R900744835 DREM20-5X/200YG24K4V 744835

R900742502 ZDREE10VP4-1X/100XLMG24NK31M 742502

R900733935 DREE10-5X/50YG24NK31M 733935

R900726891 DREM10-5X/200YG24K4V 726891

R900723160 DRE6-1X/100MG24K4V 723160

R900718469 DREME20-5X/315YG24K31V 718469

R900717553 3DREPE6A-2X/45EG24K31/A1V 717553

R900712624 DRE6-1X/50MG24K4V 712624

R900712540 ZDREE10VP1-1X/315XLMG24NK31M 712540

R900710080 ZDRE10VP1-1X/200XYMG24NK4V 710080

R900708361 DREM10-5X/50YMG24NK4M 708361

R900705978 DREE20-5X/200YG24K31M 705978

R900705197 3DREME10P-6X/315YG24K31V 705197

R900705140 3DRE16P-6X/200YG24K4V 705140

R900704208 DREM20-5X/100YMG24NK4V 704208

R900702065 ZDRE10VP1-1X/100LMG24NK4V 702065

R900700593 3DREPE6C-2X/16EG24N9K31/A1V 700593

R900617992 ZDRE6VP1-1X/50MG24K4M 617992

R900617983 DREM20-5X/315YG24K4V 617983

R900616690 ZDREE10VP1-1X/100XLMG24NK31M 616690

R900582096 DRE10-5X/100YMG24K4M 582096

R900580607 DREMCH30-4X/200YM 580607

R900573750 3DREP6C-1X/25A24N9K4V 573750

R900573377 ZDRE10VP2-1X/200XLMG24NK4M 573377

R900556315 DREM20-5X/100YG24K4M 556315

R900551330 3DREP6C-1X/25A24NK4V 551330

R900550096 3DREP6C-1X/16A24N9K4M 550096

R900548837 DRE6-1X/100MG24NK4M 548837

R900547399 ZDRE10VP2-1X/200YMG24NK4M 547399

R900547100 3DREP6C-1X/25A24N9K4M 547100

R900546913 DRE20-5X/200YMG24K4M 546913

R900498485 3DREP6C-1X/25A12NK4M 498485

R900498469 3DREP6A-1X/25A12NK4M 498469

R900496940 DRE4K-3X/30G12-22NK4M 496940

R900494199 3DREP6A-1X/45A24NK4M 494199

R900494198 3DREP6A-1X/45A24NK4V 494198

R900494195 3DREP6B-1X/45A24NK4M 494195

R900494191 3DREP6C-1X/45A24NK4M 494191

R900494190 3DREP6C-1X/45A24NK4V 494190

R900494175 3DREP6A-1X/25A24NK4M 494175

R900494171 3DREP6B-1X/25A24NK4M 494171

R900494167 3DREP6C-1X/25A24NK4M 494167

R900494165 3DREP6C-1X/25A24K4M 494165

R900494159 3DREP6B-1X/16A24NK4M 494159

R900494155 3DREP6C-1X/16A24NK4M 494155

R900481252 DRE4K-3X/30G12-22K4V 481252

R900462346 DRE4K-3X/18G12-14NK4M 462346

R900451448 3DREP6A-1X/45A24N9K4M 451448

R900426653 DRE4K-3X/18G12-14K4M 426653

R900420674 DRE4K-3X/18G24-10NK4M 420674

R900404393 DRE4K-3X/18G12-22K4M 404393

R900248789 ZDREE10VP4-1X/315XLMG24NK31M 248789

R900245955 ZDREE10VP1-1X/200YMG24NK31M 245955

R900244331 3DRE10P-6X/315YG24K4V 244331

0811402300 DREBE6X-1X/310MG24K0A1M 0811402300-0

0811402183 ZDRE6VP1X-1X/180YG24-25Z4M 0811402183-0

0811402182 ZDRE6VP1X-1X/180G24-25Z4M

0811402171 ZDRE10VP3X-1X/250YMG24-8Z4M 0811402171-0

0811402170 ZDRE10VP4X-1X/250YMG24-8Z4M-7 0811402170-0

0811402166 ZDRE10VP4X-1X/250YMG24-8Z4M

0811402165 ZDRE10VP2X-1X/180LG24-25Z4M-8

0811402163 ZDREBE10VP3X-1X/250YG24K0B5M


比例式减压阀 阀门利用阀体内部活塞两端截面积不同产生的压力差,改变阀后的压力达到减压的目的,比例准确,工作平稳,寿命长,适用温度高,既可减动压,又可减静压,水平、垂直安装均可。


比例式减压阀,外形美观,质量可靠,比例准确,工作平稳,既减动压也减静压。 该阀利用阀体内部活塞两端不同载面积产生的压力差,改变阀后的压力,达到减压目的。比例式减压阀的减压比例是:2∶1,3∶1,4∶1,3∶2,5∶2等,亦可根据要求设计特殊比例的减压阀。


比例阀当在阀后管网上无用水时阀门关闭,阀前后压力比是定值;当阀后管网启用消火栓或喷头喷水时,阀前压力大于阀后压力,推动活塞后移比例式减压阀打开,阀后管网压力随流量的增加而降低(符合流量-压力特性曲线),直至达到平衡位置,活塞停止移动。 当阀后管网停止用水时由于活塞后端压强升高,比例式减压阀活塞失去平衡状态而前移,比例式减压阀关闭。一般选择比例式减压阀是使设计流量在流量-压力特性曲线的直线段上,这样阀后压力与阀前压力仍呈比例关系。


在线咨询
  • 在线时间

  • 周一至周五
    8:30-18:00
    周六9:00-12:00